Ransburg HV Junctin Tank LEPS5000 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Ransburg HV Junctin Tank LEPS5000. Ransburg HV Junctin Tank LEPS5000 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 26
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
SERVICE MANUAL
CP-98-01.3
(Replaces CP-98-01.2)
April - 2013
HIGH VOLTAGE JUNCTION TANK
MODEL: LEPS5000
IMPORTANT: Before using this equipment,
carefully read SAFETY PRECAUTIONS, starting
on page 1, and all instructions in this manual.
Keep this Service Manual for future reference.
Service Manual Price: $30.00 (U.S.)
Ransburg
Vue de la page 0
1 2 3 4 5 6 ... 25 26

Résumé du contenu

Page 1 - Ransburg

SERVICE MANUALCP-98-01.3(Replaces CP-98-01.2)April - 2013HIGH VOLTAGE JUNCTION TANKMODEL: LEPS5000IMPORTANT: Before using this equipment, carefully

Page 2

INSTALLATIONFigure 1a: Typical System (Bells)HV Junction Tank - Installation7RansburgCP-98-01.3

Page 3 - CONTENTS

Figure 1b: Typical System (Guns)HV Junction Tank - Installation8RansburgCP-98-01.3

Page 4

> This manual MUST be read and thor-oughly understood by ALL personnel who operate, clean and maintain this equipment. Special care should be take

Page 5

> Whenever removing high voltage cable(s) from equipment, ground the plug end of the cable(s) by contacting the plug to electrical ground. Do not t

Page 6

Figure 2a: High Voltage ConnectionsFigure 2b: High Voltage Connections for the REAIII GunHV Junction Tank - Installation11RansburgCP-98-01.3

Page 7

Figure 3: Junction Tank Top ViewHV Junction Tank - Installation12RansburgCP-98-01.3

Page 8

TROUBLESHOOTING GUIDEMAINTENANCE> Electrical shock hazard. ALWAYS turn power to equipment OFF prior to cleaning or servicing any part of the system

Page 9 - INTRODUCTION

Figure 4: Troubleshooting Guide (Continued)General Problem Cause SolutionNo High Voltage (Single Output)Erratic High Voltage Output (All Outputs)-or-

Page 10 - INSTALLATION

PARTS IDENTIFICATIONFigure 5: LEPS5000 Junction Tank - Parts IdenticationHV Junction Tank - Parts Identication15RansburgCP-98-01.3

Page 11

--- Select Output Below High Voltage Junction Tank LEPS5000-01 300 megohm LEPS5000-02 75 megohm LEPS5000-03 150 megohm LEPS5000-04 450 mego

Page 12

NOTE: This manual has been changed from revision CP-98-01.2 to revision CP-98-01.3. Reasons for this change are noted under “Manual Change Summar

Page 13

WARRANTY POLICIESLIMITED WARRANTYRansburg will replace or repair without charge any part and/or equipment that falls within the specied time (see bel

Page 14

PAINT AND SOLVENT SPECIFICATIONSAEROBELL® II*** AEROBELL®AEROBELL® 33 RMA-101TM18 TO 30 SEC.1 MW TO W1000 cc/minTURBODISKTMNO. 2 HAND GUNREMTM / M90T

Page 15

VISCOSITY CONVERSION CHARTPoise.1.15.2.25.3.4.5.6.7.8.91.01.21.41.61.82.02.22.42.62.83.03.23.43.63.84.04.24.44.64.85.05.56.07.08.09.010.011.012.0Centi

Page 16 - MAINTENANCE

VISCOSITY CONVERSION CHART (Continued)Poise13.014.015.016.017.018.019.020.021.022.023.024.025.030.035.040.045.050.055.060.065.070.075.080.085.090.095.

Page 17

LengthVOLUMETRIC CONTENT OF HOSE OR TUBE(English Units)I.D. (inches)5ft. (60") 1/83/161/45/163/81/22.45.49.715.121.738.6.012.028.049.077.110.19

Page 18 - PARTS IDENTIFICATION

MANUAL CHANGE SUMMARYThis manual was published to replace Service Manual CP-98-01.3, High Voltage Junction Tank, to make the following changes:1. Add

Page 19

Service Manual Price: $30.00 (U.S.)Form No. CP-98-02.3Litho in U.S.A.04/13© 2013 Ransburg. All rights reserved.Models and specications subject to ch

Page 20 - WARRANTY POLICIES

SAFETY:SAFETY PRECAUTIONS...HAZARDS / SAFEGUAR

Page 21 - APPENDIX

W A R N I N G!W A R N I N G!SAFETYSAFETY PRECAUTIONSBefore operating, maintaining or servicing any Ransburg electrostatic coating system, read and u

Page 22

Spray AreaAREATells where hazards may occur.HAZARDTells what the hazard is.SAFEGUARDSTells how to avoid the hazard.Fire HazardImproper or inadequate o

Page 23

AREATells where hazards may occur.HAZARDTells what the hazard is.SAFEGUARDSTells how to avoid the hazard.Spray AreaImproper operation or mainte-nance

Page 24

AREATells where hazards may occur.HAZARDTells what the hazard is.SAFEGUARDSTells how to avoid the hazard.Spray Area / High Voltage EquipmentElectrical

Page 25 - MANUAL CHANGE SUMMARY

Toxic SubstancesCertain material may be harmful if inhaled, or if there is contact with the skin.Follow the requirements of the Material Safety Data S

Page 26 - Litho in U.S.A

SPECIFICATIONSInput High Voltage: 100 kVDC maximum continuousOutput High Voltage: Six outputs; equal to or less than the input voltage depending on

Commentaires sur ces manuels

Pas de commentaire