Ransburg HV Controller A12311 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Ransburg HV Controller A12311. Ransburg HV Controller A12311 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 25
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
SERVICE MANUAL
LN-9623-00.1
March - 2013
MODEL: A12311
IMPORTANT: Before using this equipment, care-
fully read SAFETY PRECAUTIONS, starting on
page 1, and all instructions in this manual. Keep
this Service Manual for future reference.
HIGH VOLTAGE
CONTROLLER
Service Manual Price: €25.00 (Euro)
$30.00 (U.S.)
Ransburg
Vue de la page 0
1 2 3 4 5 6 ... 24 25

Résumé du contenu

Page 1 - Ransburg

SERVICE MANUALLN-9623-00.1March - 2013MODEL: A12311IMPORTANT: Before using this equipment, care-fully read SAFETY PRECAUTIONS, starting on page 1, an

Page 2 - CONTENTS

PASSWORD PROTECTIONHigh Voltage Controller parameters will be pass-word protected to prevent an unqualied operator from changing the values.OPERATOR

Page 3

NOTESFault LEDThe red Fault LED is lit when the system detects a fault condition (see "Figure 3 - Power Switch" in this section). When oper

Page 4

INSTALLATIONINSTALLATIONFigure 4: InstallationMOUNTINGUsing four (4) each 10" X 32" or M-5 screws (not included), secure the front panel of

Page 5

Figure 6: Ethernet ConnectorETHERNET CONNECTORUse the appropriate 10/100BASE Ethernet wiring (Straight EIA/TIA 568A) for your installation us-ing a R

Page 6

OPERATIONMENUS AND OPERATIONOn all of the menus, if there is a parameter that can be changed there are a number of "#" char-acters to show t

Page 7

Mode MenuFigure 11: Voltage Mode ScreenThis menu displays the current mode (Voltage or Current) and the high and low limits allowed for the Dependen

Page 8 - INTRODUCTION

IP Address MenuFigure 14: IP Address Menu ScreenThis menu allows the setting of the units IP Address. When the new IP Address has been entered, the

Page 9

CONTROL CONDITIONSPower UpOn power up, the system does several checks to determine hardware status. It checks various sig-nals to determine that ther

Page 10

ETHERNET IP INPUT BIT DEFINITIONS TABLE 1ETHERNET IP INTERFACEThe Ethernet IP Interface is dened as a set of four 16 bit IO words of input and a set

Page 11

Input Word 0Bit 0 - Enable Control When this bit is set (high) the system will attempt to keep the actual at the appropriate setpoint.Bit 1 - R

Page 12 - INSTALLATION

SAFETY:SAFETY PRECAUTIONS...HAZARDS / SAFEGUARDS

Page 13

ETHERNET IP OUTPUT BIT DEFINITIONS TABLE 2High Voltage Controller - Operation18RansburgLN-9623-00.1

Page 14 - OPERATION

Output Word 0Bit 0 - In Control This bit is set when control is enabled and the control value has closed within three of the setpoint. This doe

Page 15

Bit 14 - Over Current Fault The current value has exceeded the Current (I) Limit Hi or the Max System Limit.Bit 15 - Cable Fault This bit is se

Page 16

MAINTENANCETROUBLESHOOTING GUIDEGeneral Problem Procedure SolutionBlank DisplayFaults1. If the display is blank on initial power-up, it may be that

Page 17

WARRANTY POLICIESLIMITED WARRANTYRansburg will replace or repair without charge any part and/or equipment that falls within the specied time (see bel

Page 18

Form No. LN-9623-00.1Litho in U.S.A.03/13© 2013 Ransburg. All rights reserved.Models and specications subject to change without notice.Manufacturing

Page 19

W A R N I N G!W A R N I N G!SAFETYSAFETY PRECAUTIONSBefore operating, maintaining or servicing any Ransburg electrostatic coating system, read and u

Page 20

Spray AreaAREATells where hazards may occur.HAZARDTells what the hazard is.SAFEGUARDSTells how to avoid the hazard.Fire HazardImproper or inadequate o

Page 21

AREATells where hazards may occur.HAZARDTells what the hazard is.SAFEGUARDSTells how to avoid the hazard.Spray AreaImproper operation or mainte-nance

Page 22

AREATells where hazards may occur.HAZARDTells what the hazard is.SAFEGUARDSTells how to avoid the hazard.Spray Area / High Voltage EquipmentElectrical

Page 23 - MAINTENANCE

Toxic SubstancesCertain material may be harmful if inhaled, or if there is contact with the skin.Follow the requirements of the Material Safety Data S

Page 24 - WARRANTY POLICIES

INTRODUCTIONGENERAL DESCRIPTIONThe Ransburg High Voltage Controller (A12311-00 or FRA # EE-4526-300), in conjunction with an appropriate cascade (A122

Page 25 - $30.00 (U.S.)

SPECIFICATIONSOperating Temperature: 0°C to +55°CStorage and ShippingTemperature: -40°C to +85°CHumidity: 95% Non-CondensingPhysical Size:

Commentaires sur ces manuels

Pas de commentaire